 INSTRUCTION MANUAL JFS0750 SERIES
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
RATINGS AND SPECIFICATIONS FOR LAMBDA MODEL NO. JFS0750: I. MAXIMUM RATINGS SPECIFICATION OUTPUT VOLTAGE RANGE MAXIMUM OUTPUT CURRENT (POWER) AT 50C (AT VOUTNOM) MAXIMUM OUTPUT CURRENT (POWER) AT 60C (AT VOUTNOM) MAXIMUM OUTPUT CURRENT (POWER) AT 70C (AT VOUTNOM) OPERATING TEMPERATURE
UNITS V A (W)
JFS0750-24 20-29 31.2 (750)
JFS0750-48 36-56 15.6 (750)
A (W)
23.4 (562)
11.7 (562)
A (W)
15.6 (375)
7.8 (375)
C
CONTINUOUS DUTY FROM -20C TO +70C THIRTY MINUTE WARM-UP REQUIRED AT -20C
II. INPUT SPECIFICATIONS SPECIFICATION INPUT VOLTAGE RANGE INPUT CURRENT (RMS) INPUT CURRENT (PEAK, AT COLD START) INPUT POWER (MAXIMUM) INPUT SURGE PROTECTION INPUT EMI, CONDUCTED EMISSIONS EFFICIENCY AT POUTMAX POWER FACTOR CORRECTION AT POUTMAX INPUT CURRENT HARMONICS III. OUTPUT SPECIFICATIONS SPECIFICATION LINE AND LOAD REGULATION RIPPLE AND NOISE AT 20 MHz MEASUREMENT BANDWIDTH (0-70C) PER EIAJ METHOD TEMPERATURE DRIFT HOLD-UP TIME LOAD TRANSIENT RESPONSE ( 25% LOAD CHANGE) ESD SUSCEPTIBILITY
UNITS VAC A A W -- -- % % --
JFS0750-48 85-265 (47-63 Hz.) 9.0 AT 110VAC 35 AT 110VACIN 70 AT 220VACIN 1050 AT 85 VACIN COMPLIANT TO IEC1000-4-5, LEVEL 3 STANDARDS FCC CFR PART 15, SUBPART J CLASS A STANDARDS EN55022 CLASS A STANDARDS 75 TYPICAL AT 85VACIN 99 TYPICAL, PER IEC1000-3-2 STANDARDS COMPLIANT WITH EN60555-2 ABOVE TEN PERCENT RATED POWER
JFS0750-24
UNITS % mV
JFS0750-24 JFS0750-48 1 FROM NO LOAD TO FULL LOAD, 85-265VAC 250PEAK TO PEAK 500PEAK TO PEAK
% ms -- --
2 OVER TEMPERATURE RANGE AND LIFE OUTPUT REMAINS ABOVE VOUTMIN LIMIT FOR 16ms UPON REMOVAL OF INPUT VOLTAGE AT Vin Nom (110Vac) RECOVERY TO WITHIN TWO PERCENT OF OUTPUT WITHIN 5ms. IEC1000-4-2 LEVEL 4 (8kV DIRECT DISCHARGE) STANDARDS
IV. OPERATING MODES DESCRIPTION PARALLEL OPERATION (ACTIVE CURRENT SHARE CONFIGURATION)
OPERATIONAL DEFINITION REFER TO JFS SERIES APPLICATION NOTES
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 1 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
FEATURES: I. DC OUTPUT, CONTROLS AND INDICATORS DESCRIPTION OPERATIONAL DEFINITION OUTPUT VOLTAGE ADJUST FACTORY SET AT 24VDC OR 48VDC. CONSULT FACTORY FOR ADJUSTMENT. IT IS RECOMMENDED THAT THE VOLTAGE ADJUST POTENTIOMETER BE SEALED WITH RTV SEALANT AFTER ADJUSTMENT TO PREVENT OUTPUT VOLTAGE DRIFT IN THE EVENT THAT THE UNIT IS SUBJECTED TO VIBRATION. OVERVOLTAGE PROTECTION FACTORY SET AT 30VDC OR 60VDC. CONSULT FACTORY FOR ADJUSTMENT ADJUST (NON LATCHING). OUTPUT- GOOD INDICATOR GREEN-COLORED LED ILLUMINATES WHEN THE OUTPUT VOLTAGE IS WITHIN THE SPECIFIED OPERATING RANGE. II. REMOTE CONTROL FEATURES DESCRIPTION OPERATIONAL DEFINITION REMOTE VOLTAGE SENSING PROVIDES PRECISE REGULATION DIRECTLY AT LOAD. THE MAXIMUM TOTAL DC VOLTAGE DROP BETWEEN THE OUTPUT TERMINALS AND THE LOAD MUST BE LIMITED TO LESS THAN 1.0 VOLT. REMOTE ON-OFF CONTROL DC OUTPUT IS INHIBITED VIA A CONTACT CLOSURE BETWEEN PINS 7 AND 8 OF THE TERMINAL STRIP. SIGNAL ISOLATION REMOTE ON-OFF PINS ARE REFERENCED TO THE -VOUT TERMINAL. REMOTE VOLTAGE CONTROL ALLOWS ADJUSTMENT OF OUTPUT VOLTAGE USING EXTERNAL PROGRAMMING RESISTOR OR VOLTAGE SOURCE. REFER TO JFS SERIES APPLICATION NOTES; SEE FIGURES 3 AND 4 FOR CONNECTION DIAGRAMS.
III. AUXILIARY MONITORING AND ALARM SIGNALS -- OPTICALLY COUPLED, CONDUCTANCE OUTPUTS. (CONDUCT UP TO 5mA AT A VOLTAGE OF LESS THAN 1.0VDC WHEN ACTIVE.) DESCRIPTION OPERATIONAL DEFINITION AC FAIL SIGNAL CONDUCTANCE SIGNAL WHICH INDICATES SUFFICIENT AC INPUT IS PRESENT TO PROVIDE A MINIMUM OF FIVE MILLISECONDS OF HOLD-UP TIME AFTER THE REMOVAL OF INPUT. OUTPUT GOOD SIGNAL CONDUCTANCE SIGNAL WHICH INDICATES THAT DELIVERED OUTPUT VOLTAGE, AS MEASURED AT THE +V AND -V TERMINALS IS WITHIN THE SPECIFIED OPERATING RANGE. SIGNAL ISOLATION SIGNALS ARE ISOLATED FROM POWER SUPPLY OUTPUT AND EACH OTHER FOR VOLTAGES UP TO 500VDC MAXIMUM AND 3000VAC ISOLATION FROM AC INPUT TO AUXILIARY SIGNALS.
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 2 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
FEATURES (CONT'D) IV. PROTECTION FEATURES DESCRIPTION OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION THERMAL PROTECTION (OVERTEMPERATURE PROTECTION) ISOLATION VOLTAGES
OPERATIONAL DEFINITION OUTPUT CURRENT IS LIMITED TO APPROXIMATELY 110 PERCENT OF 50C RATED POWER FROM VOUTMAX TO VOUTNOM. CURRENT LIMIT CHARACTERISTICS WILL PROVIDE FOLDBACK TO APPROXIMATELY 80 PERCENT OF RATED CURRENT BELOW VOUTNOM. INVERTER SHUTDOWN, NON-LATCHING. CONSULT FACTORY FOR ADJUSTMENT. SELF-RESETTING INVERTER SHUTDOWN.
LEAKAGE CURRENT (AC LINE TO CHASSIS GROUND) REGULATORY AGENCY COMPLIANCE
3000VAC, INPUT TO OUTPUT 500VDC, OUTPUT TO CHASSIS GROUND 1500VAC, INPUT TO CHASSIS GROUND LESS THAN 3.5mA WHEN OPERATED AT 250VAC (47-63Hz) OR LOWER VOLTAGES. JFS SERIES POWER MODULES ARE COMPLIANT WITH THE FOLLOWING STANDARDS: * UL1950 * CSA 22.2-234 * EN60950 * CE MARKED FOR EUROPEAN COMMUNITY COMPLIANCE * IEC950
V. MECHANICAL FEATURES SPECIFICATION STORAGE TEMPERATURE (NON-OPERATING) OPERATING TEMPERATURE
UNITS C C
JFS0750-24 -40 TO +85
JFS0750-48
WEIGHT (NET) WEIGHT (SHIP) SIZE (L x W x H) FINISH MOUNTING VI. OTHER FEATURES DESCRIPTION COOLING FUNGUS INERT GUARANTEE
LBS LBS INCHES -- --
-20 TO +70 WITH DERATING ABOVE +50 (-20 OPERATION REQUIRES A THIRTY MINUTE WARM-UP PERIOD) 7.5 8.5 12.81 x 5.00 x 3.30 (INCLUDES MOUNTING FLANGE) GRAY SEE OUTLINE DRAWING FOR MOUNTING
DEFINITION FORCED AIR, FAN COOLED FROM THE FRONT OF THE POWER SUPPLY EXITING AT THE CONNECTOR END. ALL JFS POWER SUPPLIES ARE INHERENTLY FUNGUS INERT. FIVE YEARS FROM THE TIME OF DELIVERY, PARTS AND LABOR.
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 3 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
VII. CONNECTOR INFORMATION SENSING AND DESIGNATION SIGNAL 1 +S 2 3 4 5 +LS -LS -S PROG DESCRIPTION +SENSE CONNECTION. CONNECT TO +V TERMINAL OF LOAD FOR REMOTE-SENSING. CONNECT TO +LS FOR LOCAL SENSING. +LOCAL SENSE CONNECTION -LOCAL SENSE CONNECTION -SENSE CONNECTION. CONNECT TO -V TERMINAL OF LOAD FOR REMOTE-SENSING. CONNECT TO -LS FOR LOCAL SENSING. JUMPER TO PIN 4 (-S) FOR INTERNAL PROGRAMMING. ALLOWS FOR REMOTE, EXTERNAL PROGRAMMING VIA INSERTION OF RESISTOR BETWEEN THE PROGRAMMING PIN AND PIN 4 (-S). CURRENT SHARE BUSS FUNCTIONS TO ENABLE AND DISABLE THE INVERTER OF THE POWER SUPPLY. A DIRECT SHORT TO INTERLOCK 2 (PIN 8) THROUGH A CONTACT CLOSURE WILL INHIBIT THE UNIT. AN OPEN CIRCUIT TO INTERLOCK 2 WILL ENABLE POWER SUPPLY. (SEE DESCRIPTION, PIN 7) OPEN COLLECTOR SIGNAL INDICATING THAT A FAULT CONDITION HAS OCCURRED ON THE AC LINE. THIS PIN REPRESENTS THE COLLECTOR OF THE INTERNAL OPTO-TRANSISTOR CAPABLE OF SINKING UP TO 5mA WITH 20 VOLTS MAXIMUM APPLIED FROM COLLECTOR TO EMITTER. REPRESENTS THE EMITTER OF THE INTERNAL OPTO-TRANSISTOR CAPABLE OF SINKING UP TO 5mA WITH 20 VOLTS MAXIMUM APPLIED FROM COLLECTOR TO EMITTER. OPEN COLLECTOR SIGNAL INDICATING THE OUTPUT IS PRESENT. THIS PIN REPRESENTS THE COLLECTOR OF THE INTERNAL OPTOTRANSISTOR CAPABLE OF SINKING UP TO 5mA WITH 20 VOLTS MAXIMUM APPLIED FROM COLLECTOR TO EMITTER. REPRESENTS THE EMITTER OF THE INTERNAL OPTO-TRANSISTOR CAPABLE OF SINKING UP TO 5mA WITH 20 VOLTS MAXIMUM APPLIED FROM COLLECTOR TO EMITTER.
6 7
ISHARE INTLK 1
8 9
INTLK 2 AC FAIL 1
10
AC FAIL 2
11
DC GOOD 1
12
DC GOOD 2
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 4 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
Lambda JFS Series Safety and Installation Instructions for Lambda Model JFS0750 To comply with published safety standards; the following instructions must be used in conjunction with the Lambda JFS Series: For earth fault protection, the unit must be protected in the final installation by suitable overcurrent protection means. If protection relies upon building wiring, the end product installation must ensure that the necessary protection is provided. The internal fuse F101 may only be replaced with a Littelfuse type 324015 rated at 15A, 250VAC. The internal fuse F102 may only be replaced with Littelfuse type 324020 rated at 20A, 250VAC. The power supply is intended for use as a component of other equipment. When installing the power supply, the relevant safety standards (EN60950, IEC950, UL1950 or CSA-22.2-950) must be complied with. In particular, creepage and clearance distances and distances through insulation between primary and earth or primary and secondary must be maintained. The power supply output is SELV in accordance with requirements IEC-950. The output available has power greater than 240VA. The CE mark on the product is applied to show conformance with the requirements outlined in the European Union's Low Voltage Directive [72/23/EEC] as amended by the CE Mark Directive [93/68/EEC]. The maximum ambient temperature of the operating environment must not exceed 50C at 750W, 60C at 562W or 70C at 375W.
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 5 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
Sicherheits und Installationsanleitung fur Lambda Modell JFS0750 Die folgende Sicherheitshinweise mussen bei der Verwendung der Netzteile beachtet werden: Gegen Isolationsfehler zum Schutzleiter mu in der Endanwendung eine angemessene Absicherung vorgenommen werden. Falls die Absicherung durch die Gebaudeinstallation erfolgt, mu beim Einbau in das Endgerat entsprechend darauf hingewiesen werden. Die interne Sicherung F101 darf nur gegen den gleichen Typ mit gleichen Werten ausgetauscht werden. Es ist die Sicherung Littelfuse Typ 324015 mit 15A und 250VAC zu verwenden. Die interne Sicherung F102 darf nur gegen den gleichen Typ mit gleichen Werten ausgetauscht werden. Es ist die Sicherung Littelfuse Typ 324020 mit 20A und 250VAC zu verwenden. Das Netzteil ist nur als Baugruppe zum Einbau in Endgerate vorgesehen und nicht zur eigenstandigen Verwendung. Beim Einbau in Endgerate sind die entsprechenden Sicherheitsbestimmungen (z. B. EN 60950, IEC-950, UL-1950, CSA 22.2-950) zu beachten. Im Speziellen ist auf das Einhalten ausreichender Kriech- und Luftstrecken sowie Isolationsabstaenden zwischen dem Primaer- und Sekundaerkreis sowie zum Schutzleiter zu achten. Das Netzteil liefert eine SELV-Spannung in Uebereinstimmung mit IEC-950. Die verfuegbare Ausgangsleistung ist groeer als 240VA. Das CE-Konformitaetszeichen auf dem Produkt zeigt die Uebereinstimmung mit den Anforderungen der EG-Niederspannungs-Richtlinie [72/23/EWG] und der Ergaenzung [93/68/EWG]. Die maximale Arbeitsumgebungstemperatur darf 50C bei 750W, 60C bei 562W und 70C bei 375W nicht ueberschreiten. Die Sicherung mu im L-Leiter (Phase) eingefuegt werden.
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 6 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 7 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
FIGURE 1: TYPICAL LOCAL SENSE CONNECTION
FIGURE 2: TYPICAL REMOTE SENSE CONNECTION
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 8 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
FIGURE 3: REMOTE VOLTAGE CONTROL WITH AN EXTERNAL PROGRAMMING RESISTOR OR VOLTAGE SOURCE (LOCAL SENSING)
FIGURE 4: REMOTE VOLTAGE CONTROL WITH AN EXTERNAL PROGRAMMING RESISTOR OR VOLTAGE SOURCE (REMOTE SENSING)
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 9 IMJFS07 - REV A
JFS SERIES INSTRUCTION MANUAL
FIGURE 5: PARALLEL OPERATION
LAMBDA ELECTRONICS INCORPORATED 515 BROAD HOLLOW ROAD, MELVILLE, NY 11747-3700 * TEL: 516-694-4200 * FAX: 516-293-0519 P. 10 IMJFS07 - REV A


▲Up To Search▲   

 
Price & Availability of JFS0750-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X